C00581
C00582
Parameter | Name:
C00581 | Resp. to LS_SetError_x
Data type: UNSIGNED_8
Index: 23994
d
= 5DBA
h
Selection of the error responses for application error messages
• An application error message is tripped by a FALSE/TRUE edge at the binary inputs bSetError1...4.
Selection list
0 No Reaction
1 Fault
2 Trouble
3 TroubleQuickStop
4 WarningLocked
5 Warning
6 Information
Subcodes
Lenze setting
Info
C00581/1
0: No Reaction
: Resp. to bSetError1
C00581/2
0: No Reaction
: Resp. to bSetError2
C00581/3
0: No Reaction
: Resp. to bSetError3
C00581/4
0: No Reaction
: Resp. to bSetError4
C00581/5
0: No Reaction
: Resp. to bSetError1
C00581/6
0: No Reaction
: Resp. to bSetError2
C00581/7
0: No Reaction
: Resp. to bSetError3
C00581/8
0: No Reaction
: Resp. to bSetError4
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00582 | Resp. to heatsink temp. > shutdown temp. -5°C
Data type: UNSIGNED_8
Index: 23993
d
= 5DB9
h
Response if the heatsink temperature has reached the switch-off temperature threshold.
Selection list
(Lenze setting printed in bold)
0 No Reaction
1 Fault
5 Warning
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1