3 multi-encoder (x8), Multi-encoder (x8), 6encoder/feedback system – Lenze 8400 TopLine User Manual
Page 325
![background image](/manuals/566308/325/background.png)
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
325
6
Encoder/feedback system
6.3
Multi-Encoder (X8)
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
6.3
Multi-Encoder (X8)
The interface of the Multi-Encoder offers various ways in which the encoders can be used /
evaluated:
•
Incremental TTL and SinCos encoder
•
SinCos absolute value encoder with HIPERFACE® protocol
•
SSI absolute value encoder with Stegmann-SSI protocol
•
(from version 12.00.00)
Danger!
• If the resolver is used as motor encoder:
Safe operation of the motor is no longer ensured in the event of an error!
• If servo control (SC) or V/f control (VFCplus + encoder) are used: For safety reasons,
always select "Fault" (Lenze setting) in
as a response for the (open-circuit)
monitoring of the encoder!
Stop!
Before connecting an encoder, ensure that the encoder supply voltage has the correct
setting in
:
• Lenze setting: 5 V (setting range: 5 ... 12 V)
If the set supply voltage exceeds the permissible supply voltage of the connected
encoder, the encoder may be destroyed!
Note!
With regard to their position resolution, higher-level applications are based on the
resolution of the encoder which is activated for position control.