C00569
C00570
Parameter | Name:
C00569 | Resp. to peak current
Data type: UNSIGNED_8
Index: 24006
d
= 5DC6
h
Configuration of monitoring of the motor control (group 1)
Selection list
0 No Reaction
1 Fault
5 Warning
Subcodes
Lenze setting
Info
C00569/1
0: No Reaction
Response for overcurrent detection and clamp operation
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00570 | Resp. to controller limitations
Data type: UNSIGNED_8
Index: 24005
d
= 5DC5
h
Configuration of monitoring of the motor control (group 2)
Selection list
0 No Reaction
1 Fault
5 Warning
Subcodes
Lenze setting
Info
C00570/1
0: No Reaction
Response if direct-axis current controller is limited
• e.g. at servo control (
C00570/2
0: No Reaction
Response if cross current controller is limited
• e.g. at servo control (
C00570/3
0: No Reaction
Response if torque setpoint is limited
• Limitation of the speed controller output, the
differential setpoint precontrol, and of the additive
torque at (
) servo control and (
) sensorless
vector control.
C00570/4
0: No Reaction
Response if field controller is limited
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1