5 speed follower, 1 parameter setting, 1 functional settings – Lenze 8400 TopLine User Manual
Page 604: Speed follower, Parameter setting, Functional settings, Reques, 9basic drive functions (mck)
![background image](/manuals/566308/604/background.png)
9
Basic drive functions (MCK)
9.5
Speed follower
604
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
9.5
Speed follower
In the "speed follower" operating mode, the drive follows a speed setpoint.
9.5.1
Parameter setting
Short overview of parameters for the "speed follower" operating mode:
9.5.1.1
Functional settings
In
, various functional settings for the speed follower can be made in bit-coded form.
Parameter
Info
Lenze setting
Value Unit
MCK: Speed follower setting
Bit coded
MCK: Ramp time synchr. setpoint
2.000 s
MCK: Pos. max. speed
199.99 %
MCK: Pos. min. speed
0.00 %
MCK: Neg. min. speed
0.00 %
MCK: Neg. max. speed
199.99 %
Function
Lenze setting
Bit 0 Reserved
Off
Bit 1 Reserved
Off
Bit 2 HW limit switch on
In the "speed follower" operating mode, a travel range monitoring mode via
hardware limit switch is active.
Limit position monitoring ( 590)
On
Bit 3 SW limit switch on
In the "speed follower" operating mode, a travel range monitoring mode via
parameterised software limit positions.
Limit position monitoring ( 590)
On
Bit 4 Reserved
Off
Bit 5 Reserved
Off
Bit 6 Reserved
Off
Bit 7 Position controller off
In the "Speed follower" operating mode, the position controller is
deactivated. Thus, the compensation of the following error is switched off.
Off