17 parameter reference – Lenze 8400 TopLine User Manual
Page 886
17
Parameter reference
17.2
Parameter list | C00007
886
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
TA "actuating drive speed (AC Drive Profile)"
Input/output
10: Terminals 0
12: Terminals 2
14: Terminals 11
16: Terminals 16
RFR
Controller enable / Reset of error message
DI1
Fixed setpoint 1/3
Change of direction of
rotation
Fixed setpoint 1/3
DI2
Fixed setpoint 2/3
Activate manual DC-
injection braking (DCB)
Fixed setpoint 2/3
DI3
Activate manual DC-injection
braking (DCB)
Quick stop
Motor potentiometer:
Increase speed
CW rotation quick stop
DI4
Change of direction of rotation
Motor potentiometer:
Decrease speed
CCW rotation quick stop
A1U, A1I
Local speed/torque setpoint (speed mode: 10 V ≡ 100 % reference speed; torque mode: 10 V ≡ 100 % M
max
)
O1U, O1I
Actual speed value (10 V ≡ 100 % reference speed)
DO1
Status "Drive is ready"
Relay output
Status "Error is pending"
Input/output
10: Terminals 0
12: Terminals 2
14: Terminals 11
16: Terminals 16
RFR
Controller enable / Reset of error message
DI1
-
-
Positive limit switch
-
DI2
-
-
Negative limit switch
-
DI3
Positive limit switch
-
-
Manual jog
in positive direction
DI4
Negative limit switch
Positioning profile, array bit (valency 4)
Manual jog
in negative direction
DI5
Positioning profile, array bit (valency 2)
DI6
Positioning profile, array bit (valency 1)
DI7
Start of profile generation
A1U, A1I
Main speed setpoint (10 V ≡ 100 % reference speed)
O1U, O1I
Actual speed value (10 V ≡ 100 % reference speed)
O2U, O2I
Current motor current (10 V ≡ 100 % I
max_mot
)
DO1
Status "Drive is ready"
DO2
Status "Target position (actual value) is in the target window"
DO3
Status "Home position is known"
BD1, BD2
Control of the holding brake
Relay output
Status "Error is pending"
Input/output
10: Terminals 0
12: Terminals 2
14: Terminals 11
16: Terminals 16
RFR
Controller enable
Controller enable / Reset of error message
DI1
Fixed setpoint 1/3
Stop function 1
Fixed setpoint 1/3
DI2
Fixed setpoint 2/3
Stop function 2
Selection: Pre-switch off 1
Fixed setpoint 2/3
DI3
Reset error message
CW rotation quick stop
Selection: Switch-off position 1
CW rotation quick stop
DI4
Change of direction of
rotation
CCW rotation quick stop
Selection: Switch-off position 2
CCW rotation quick stop
DI5
-
-
Stop function 2
-
DI6
-
-
Selection: Pre-switch off 2
-
A1U
Main speed setpoint (10 V ≡ 100 % reference speed)
BD1, BD2
Control of the holding brake