2 parameterising the encoder, Parameterising the encoder, 6encoder/feedback system – Lenze 8400 TopLine User Manual
Page 330
6
Encoder/feedback system
6.3
Multi-Encoder (X8)
330
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
6.3.2.2
Parameterising the encoder
Parameterisation dialog (cutout)
Further parameterisation dialogs:
Parameter
Info
Lenze setting
Value Unit
General settings
LS_MultiEncoder: Encoder type
0: Incremental encoder (TTL)
LS_MultiEncoder: Supply voltage
5.0 V
LS_MultiEncoder: Encoder increment
• Setting is relevant for process data channel
(incremental SinCos track).
512 Incr./rev.
LS_MultiEncoder: Encoder filter time
1.0 ms
LS_MultiEncoder: Position offset
0.0000 units
Settings for SinCos absolute value encoder with HIPERFACE® protocol
Hiperface: Detected TypCode
-
Hiperface: Number of revolutions
• Number of resolved revolutions of the Hiperface
track.
• Setting is relevant for parameter channel.
0
Hiperface: Steps per revolution
• Resolution of the Hiperface track.
• Setting is relevant for parameter channel.
0
Hiperface: Advanced settings
0x0
Highlighted in grey = display parameter