2 min/max speed, Min/max speed, 9basic drive functions (mck) – Lenze 8400 TopLine User Manual
Page 589
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
589
9
Basic drive functions (MCK)
9.4
Basic settings
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
9.4.2
Min/Max speed
For the "
" operating mode, yo can initially limit the speed setpoint by means of the
following parameters:
In the »Engineer», you can set the initial limit by means of the dialog box Min/Max speed.
• Open the Min/max speed dialog box by opening the Application Parameters tab and clicking on
the following button on the dialog level Overview Signal flow:
Speed setpoint generation
When the speed limit values are set, the Motion Control Kernel influences the setpoint generation
with a synchronisation mode The synchronisation mode serves to travel the synchronisation range
dynamically with the synchronisation ramp set in
. Synchronisation always starts in the
zero crossing of the defined speed.
[9-14] Example: Speed setpoint generation in the "Speed follower" operating mode (with nSpeedAddValue_v = 0)
Parameter
Info
Lenze setting
Value Unit
MCK: Ramp time synchr. setpoint
2.000 s
MCK: Pos. max. speed
199.99 %
MCK: Pos. min. speed
0.00 %
MCK: Neg. min. speed
0.00 %
MCK: Neg. max. speed
199.99 %
Setpoint range
Synchronisation range
Sync
Sync
v
t
C02611/1
C02611/2
C02611/3
C02611/4
C02610/2
0
1
0
nSpeedSetValue_a
nSpeedSetValue_a_
C02610/2