Apter, Output of the encoder position of the, Di1/di2 frequency input – Lenze 8400 TopLine User Manual
Page 393: 7i/o terminals
![background image](/manuals/566308/393/background.png)
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
393
7
I/O terminals
7.1
Digital input terminals
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
7.1.2.1
Output of the encoder position of the DI1/DI2 frequency input
The
system block includes an integrator for providing the encoder position.
• The integrator can take max. ±32000 encoder revolutions.
• The starting position can be loaded via inputs.
• The internal function can be set via parameters.
• In addition to the encoder position, the "Overflow occurred/distance processed" status signal is
provided.
Inputs
Outputs
Identifier
DIS code | data type
Information/possible settings
bPosIn12_Load
BOOL
Load angle integrator with starting value and reset status signal
TRUE Angle integrator is loaded with the value at dnPosIn12_Set_p and
bPosIn12_State is reset to FALSE.
dnPosIn12_Set_p
DINT
Starting value for angle integrator
Identifier
DIS code | data type
Value/meaning
dnPosIn12_p
DINT
Angle output signal
• 65536 [incr.] ≡ 1 encoder revolution
• Overflow is possible (display via bPosIn12_State)
bPosIn12_State
BOOL
Status signal "Overflow occurred/distance processed"
• Status signal can be reset via bPosIn12_Load.
TRUE Overflow has occurred or distance is processed.
Q)UHT,QBY
GQ3RV,QBS
&
& &RPSDUHYDOXH
)XQFWLRQ
E3RV,QB6WDWH
E3RV,QB/RDG
GQ3RV,QB6HWBS
&
',
',
N+]
N+]
&%LW
&%LW
&
&