17 parameter reference – Lenze 8400 TopLine User Manual
Page 1056
![background image](/manuals/566308/1056/background.png)
17
Parameter reference
17.2
Parameter list | C00711
1056
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00711/28
0: Not connected
: bPosDisableFollowProfile
Control input for suppression of sequence profile linkage
C00711/29
0: Not connected
: bPosStop
Control input for interruption of profile generation by
ramp-down procedure
C00711/30
0: Not connected
: bGPAnalogSwitchSet
Control input for analog-value selector change-over
C00711/31
0: Not connected
: bGPDigitalDelayIn
Input for digital signal with time delay
C00711/32
0: Not connected
: bGPLogicIn1
Input signal 1 for digital logic
C00711/33
0: Not connected
: bGPLogicIn2
Input signal 2 for digital logic
C00711/34
0: Not connected
: bGPLogicIn3
Input signal 3 for digital logic
C00711/35
0: Not connected
: bGPDFlipFlop_InD
Control input for DFlipFlop setting signal
C00711/36
0: Not connected
: bGPDFlipFlop_InClk
Control input for DFlipFlop clock signal
C00711/37
0: Not connected
: bGPDFlipFlop_InClr
Control input for DFlipFlop reset signal
C00711/38
0: Not connected
: bGPCounter1ClkUp
Control input for up-counting counter module 1
C00711/39
0: Not connected
: bGPCounter1ClkDown
Control input for down-counting counter module 1
C00711/40
0: Not connected
: bGPCounter1Load
Control input for load value acceptance in counter
module 1
C00711/41
0: Not connected
: bMckOperationMode_1
Control input for MCK operating mode changeover value
1
C00711/42
0: Not connected
: bMckOperationMode_2
Control input for MCK operating mode changeover value
2
C00711/43
0: Not connected
: bMckOperationMode_4
Control input for MCK operating mode changeover value
4
C00711/44
0: Not connected
: bMckOperationMode_8
Control input for MCK operating mode changeover value
8
C00711/45
0: Not connected
: bPosProfileNo_1
Control input for selection of profile number value 1
C00711/46
0: Not connected
: bPosProfileNo_2
Control input for selection of profile number value 2
C00711/47
0: Not connected
: bPosProfileNo_4
Control input for selection of profile number value 4
C00711/48
0: Not connected
: bPosProfileNo_8
Control input for selection of profile number value 8
C00711/49
0: Not connected
: bFreeIn1
Input for binary user signal 1
C00711/50
0: Not connected
: bFreeIn2
Input for binary user signal 2
Parameter | Name:
C00711 | LA_TabPos: Digital connection list
Data type: UNSIGNED_16
Index: 23864
d
= 5D38
h