Ck02: neg. hw limit switch [xx.0184.00002, Ck15: error status sign. brake [xx.0184.00005, Ck03: pos. sw limit position [xx.0184.00007 – Lenze 8400 TopLine User Manual
Page 725: Ck04: neg. sw limit position [xx.0184.00008, Xx.0184.00002, Xx.0184.00007, Xx.0184.00008, Xx.0184.00015, Xx.0184.00005, 10 diagnostics & error management
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
725
10
Diagnostics & error management
10.9
Error messages of the operating system
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Ck02: Neg. HW limit switch [xx.0184.00002]
Ck15: Error status sign. brake [xx.0184.00005]
Ck03: Pos. SW limit position [xx.0184.00007]
Ck04: Neg. SW limit position [xx.0184.00008]
Ck14: Target position outside SW limit position [xx.0184.00015]
Response (Lenze setting printed in bold)
Setting:
( Adjustable response)
0: No Reaction 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked 5: Warning 6: Information
Cause
Remedy
MCK: The hardware limit switch in negative traversing
direction has tripped.
• The bLimitSwitchNeg input for travel range
monitoring via negative hardware limit switch has
been set to FALSE (fail-safe).
Reset error message and retract limit switch.
Response (Lenze setting printed in bold)
0: No Reaction 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked 5: Warning 6: Information
Cause
Remedy
MCK: The status monitoring of the holding brake control
has tripped.
• Check configuration of the bMBrakeApplied input for
status detection of the brake (via a switching contact
at the brake).
• Check wiring/function of the switching contact.
• Adapt waiting time (
).
• Deactivate status monitoring (via bit 5 in
).
Response (Lenze setting printed in bold)
Setting:
( Adjustable response)
0: No Reaction 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked 5: Warning 6: Information
Cause
Remedy
MCK: The device has detected that the position is outside
the positive software limit position (
).
• Increase permissible traversing range (change setting
of the software limit positions).
• Deactivate software limit position monitoring.
Response (Lenze setting printed in bold)
Setting:
( Adjustable response)
0: No Reaction 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked 5: Warning 6: Information
Cause
Remedy
MCK: The device has detected that the position is outside
the negative software limit position (
).
• Increase permissible traversing range (change setting
of the software limit positions).
• Deactivate software limit position monitoring.
Response (Lenze setting printed in bold)
Setting:
( Adjustable response)
0: No Reaction 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked 5: Warning 6: Information
Cause
Remedy
MCK: It has been attempted to position a target outside
the software limit positions (
).
• Select a target within the software limit positions.
• Increase permissible traversing range (change setting
of the software limit positions).
• Deactivate software limit position monitoring.