Fc01: switching frequency reduction [xx.0123.00094, Fc02: maximum speed for fchop [xx.0123.00095, Oc16: torque controller limitation [xx.0123.00098 – Lenze 8400 TopLine User Manual
Page 715: Xx.0123.00094, Xx.0123.00095, Xx.0123.00096, Xx.0123.00097, Xx.0123.00098, 10 diagnostics & error management
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
715
10
Diagnostics & error management
10.9
Error messages of the operating system
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
FC01: Switching frequency reduction [xx.0123.00094]
FC02: Maximum speed for Fchop [xx.0123.00095]
oC14: Direct-axis current controller limitation [xx.0123.00096]
oC15: Cross current controller limitation [xx.0123.00097]
oC16: Torque controller limitation [xx.0123.00098]
Response (Lenze setting printed in bold)
Setting:
( Adjustable response)
0: No Reaction 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked 5: Warning 6: Information
Cause
Remedy
Load-dependent switching frequency reduction
• Observe load requirements.
• Correct dimensioning or reduce setpoint generation
dynamics if necessary.
Response (Lenze setting printed in bold)
Setting:
( Adjustable response)
0: No Reaction 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked 5: Warning 6: Information
Cause
Remedy
Maximum speed for chopper frequency has been
reached.
• The maximum speed has been exceeded depending
on the switching frequency.
Select the correct maximum speed as a function of the
switching frequency.
Motor control: Determine speed limits
Response (Lenze setting printed in bold)
Setting:
( Adjustable response)
0: No Reaction 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked 5: Warning 6: Information
Cause
Remedy
Direct-axis current controller limitation is active.
• Observe load requirements.
• Correct dimensioning or reduce setpoint generation
dynamics if necessary.
Response (Lenze setting printed in bold)
Setting:
( Adjustable response)
0: No Reaction 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked 5: Warning 6: Information
Cause
Remedy
Cross current controller limitation is active.
• Observe load requirements.
• Correct dimensioning or reduce setpoint generation
dynamics if necessary.
• Check parameter setting of the current controller
with regard to the motor controllers (e.g. reduce Vp).
Response (Lenze setting printed in bold)
Setting:
( Adjustable response)
0: No Reaction 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked 5: Warning 6: Information
Cause
Remedy
Actuator limitation according to speed controller.
• Observe load requirements.
• Correct dimensioning or reduce setpoint generation
dynamics if necessary.