C02430 | axis bus address and no. of nodes, C02430/1, C02430/2 – Lenze 8400 TopLine User Manual
Page 1263: C02315/1, C02315/2, C02315/3, C02315/4, 17 parameter reference
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
1263
17
Parameter reference
17.2
Parameter list | C02314
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02314
C02315
C02430
Parameter | Name:
C02314 | Reserved
Data type: UNSIGNED_8
Index: 22261
d
= 56F5
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C02315 | LS_WriteParamList: Manual entry of motor type
Data type: UNSIGNED_8
Index: 22260
d
= 56F4
h
From version 14.00.00 onwards
: Parameter values (1st value ... 4th value) for optional
Selection list
0 Automatic
1 ASM
2 PSM
Subcodes
Lenze setting
Info
C02315/1
0: Automatic
: c1001_s1_val1
C02315/2
0: Automatic
: c1001_s1_val2
C02315/3
0: Automatic
: c1001_s1_val3
C02315/4
0: Automatic
: c1001_s1_val4
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C02430 | Axis bus address and no. of nodes
Data type: UNSIGNED_8
Index: 22145
d
= 5681
h
From version 02.00.00
Setting range
(min. value | unit | max. value)
0
62
Subcodes
Lenze setting
Info
C02430/1
0
Axis bus address
• 0 ≡ Node is disconnected from the axis bus
• 1 ≡ Master
• 2 ... 62 ≡ slave 1 ... slave 61
C02430/2
2
Axis bus no. of nodes
• Number of slaves connected to the axis bus.
• Setting only required for the master.
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1