3working with the fb editor – Lenze E94A User Manual
Page 63

Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05
63
3
Working with the FB editor
3.4
Creating/reconfiguring the interconnection
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
How to configure a new user code:
1. Go to the Assign User Code dialog box and press the New button.
• The Create user code dialog box for configuring a new user code is displayed.
2. Configure the properties of the user code.
• See the following section "
3. Press OK.
• The Create user code dialog box is closed and the newly configured user code is listed in
the Assign User Code dialog box.
Properties of a user code
Input field
Information
Code
Code number
• The next free code number is already entered into the input field.
• The range of 3000 ... 9999 is available for user codes.
• The code number must not already be allocated within the application.
Access rights
Selection whether only read or also write access to user code should be pos-
sible.
For a user code with write access, the following properties can be configured
in addition:
Depends on
controller inhibit
Set a checkmark in this control field if the user code
should only be parameterised when the controller is
inhibited.
Dependent upon
PLC stop
Set a checkmark into this control field if the user code
should only be parameterised when the application
is stopped.
Keypad confirmation
via SH-PRG
Set a checkmark into this control field if the parame-
terisation of the user code should be confirmed using
the keypad.
Number of subcodes
Number of subcodes (0 ... 255)
• If subcodes have been defined, the initialisation values and display texts
are configured in the Initialisation values dialog box, which you open via
the Subcodes... button.
Unit
Optional text
• The unit is displayed in the »Engineer« parameter list and in the keypad
for the user code.
Scaling
Selection whether the user code is to be displayed with a linear value or a se-
lection list.
• Depending on the selection, the other possible settings for the user code
change.