beautypg.com

3working with the fb editor – Lenze E94A User Manual

Page 63

background image

Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05

63

3

Working with the FB editor

3.4

Creating/reconfiguring the interconnection

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

How to configure a new user code:

1. Go to the Assign User Code dialog box and press the New button.

• The Create user code dialog box for configuring a new user code is displayed.

2. Configure the properties of the user code.

• See the following section "

Properties of a user code

".

3. Press OK.

• The Create user code dialog box is closed and the newly configured user code is listed in

the Assign User Code dialog box.

Properties of a user code

Input field

Information

Code

Code number

• The next free code number is already entered into the input field.

• The range of 3000 ... 9999 is available for user codes.

• The code number must not already be allocated within the application.

Access rights

Selection whether only read or also write access to user code should be pos-

sible.

For a user code with write access, the following properties can be configured

in addition:
Depends on

controller inhibit

Set a checkmark in this control field if the user code

should only be parameterised when the controller is

inhibited.

Dependent upon

PLC stop

Set a checkmark into this control field if the user code

should only be parameterised when the application

is stopped.

Keypad confirmation

via SH-PRG

Set a checkmark into this control field if the parame-

terisation of the user code should be confirmed using

the keypad.

Number of subcodes

Number of subcodes (0 ... 255)

• If subcodes have been defined, the initialisation values and display texts

are configured in the Initialisation values dialog box, which you open via

the Subcodes... button.

Unit

Optional text

• The unit is displayed in the »Engineer« parameter list and in the keypad

for the user code.

Scaling

Selection whether the user code is to be displayed with a linear value or a se-

lection list.

• Depending on the selection, the other possible settings for the user code

change.