5function blocks – Lenze E94A User Manual
Page 376

5
Function blocks
5.99
L_LdVirtualMasterP - virtual master for synchronism
376
Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C05011
0.0000
Unit
214000.0000 Target position
• The target position must be inside
the cycle.
• Initialisation: 0.0000 unit
C05012
0.0000
Unit
214000.0000 Starting position
• The starting position must be
inside the cycle.
• Initialisation: 0.0000 unit
C05013/1
-214000.0000
Unit/t
214000.0000 Master speed 1
• Initialisation: 1.0000 unit/t
C05013/2
-214000.0000
Unit/t
214000.0000 Master speed 2
• Initialisation: 1.0000 unit/t
C05014/1
0.0000
Unit/t
214000.0000 Positive inching: Speed
• Initialisation: 1.0000 unit/t
C05014/2
0.0000
Unit/t
214000.0000 Negative inching: Speed
• Initialisation: 1.0000 unit/t
C05015/1
0.010
s
130.000 Ramp: Inching
• Initialisation: 1.000 s
C05015/2
0.010
s
130.000 Ramp: Continuous operation/single
cycle
• Initialisation: 1.000 s
C05015/3
0.010
s
130.000 Ramp: Stop
• Initialisation: 1.000 s
C05016/1
From library V02.02.xx.xx onwards
Character string
Position unit
• Read only
C05016/2
From library V02.02.xx.xx onwards
Character string
Speed unit
• Read only
C05017
From library V02.02.xx.xx onwards
-214748.3647
Unit/t
214748.3647 Reference speed
• Read only
• For input orientation for speed
entries.
C05024
-2147483647
2147483647 Status
• Display of the bit-coded output
signal dnState.
C05025
Master position in the target
• Like output bInTarget
• Read only
0 No
1 Yes
C05026
-214748.3647
Unit
214748.3647 Cycle
• Read only
C05027
-214748.3647
Unit
214748.3647 Master position at the output
• Display of the dnPosOut_p output
signal in the real unit of the
machine.
C05028
-214748.3647
Unit
214748.3647 External master position at the input
• Display of the dnExtMaster_p
input signal in the real unit of the
machine.
Parameter
Possible settings
Info