beautypg.com

3 function 3: dnin1_n < dnin2_n, 5function blocks – Lenze E94A User Manual

Page 561

background image

Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05

561

5

Function blocks

5.161

L_TbCompare_n - scaled comparison

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.161.3

Function 3: dnIn1_n < dnIn2_n

Selection: C04080 = "2"

• This function serves, for instance, to implement the comparison "actual speed is lower than a

limit value" (n

act

n

x

) for one direction of rotation.

[5-123] Function 3: Switching performance

Functional sequence

1. If the value at dnIn1_n falls below the value at dnIn2_n, bOut_b changes from FALSE to TRUE.
2. Only if the signal at dnIn1_n exceeds the value at dnIn2_n - C04082 again, bOut_b changes from

TRUE to FALSE.

[5-124] Function 3: Example

TRUE

FALSE

bOut

C04082

dnIn2_n

dnIn1_n

dnIn1_n

C04082

dnIn2_n

TRUE

FALSE

bOut

t

t