beautypg.com

5 monitoring for counter overflow, Monitoring for counter overflow, 5function blocks – Lenze E94A User Manual

Page 429

background image

Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05

429

5

Function blocks

5.113

L_PosProfileTable - profile data record management (simple)

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.113.5

Monitoring for counter overflow

This function extension will be available from library V2.02!

If the machine parameters transferred to the FB via the AxisData input are changed afterwards (e.g.

the gearbox factors), this may cause a counter overflow when the speed, acceleration, and position

values defined via parameters are converted from the real unit to the internal unit.
The FB causes a corresponding error message in case of an internal counter overflow due to a chan-

ged measuring system:

Error number

Error message in the logbook

Response

61736966

0x3AE0806

L_PosProfileTable:int.pos. overflow (LS_DriveInterface)

Error

61737222

0x3AE0906

L_PosProfileTable:int.pos. overflow (L_SdSetAxisData)

Error

61735942

0x3AE0406

L_PosProfileTable:int.speed overflow (LS_DriveInterface)

Error

61736198

0x3AE0506

L_PosProfileTable:int.speed overflow (L_SdSetAxisData)

Error

61735430

0x3AE0206

L_PosProfileTable:int.accel. overflow (LS_DriveInterface)

Error

61735686

0x3AE0306

L_PosProfileTable:int.accel. overflow (L_SdSetAxisData)

Error