Lenze E84AYCER User Manual
Ä.dw}ä, 8400 l-force communication
Table of contents
Document Outline
- E84AYCER communication module (PROFINET)
- Contents
- 1 About this documentation
- 2 Safety instructions
- 3 Product description
- 4 Technical data
- 5 Installation
- 6 Commissioning
- 7 Data transfer
- 8 Process data transfer
- 9 Parameter data transfer
- 10 Monitoring
- 11 Diagnostics
- 12 Error messages
- 12.1 Short overview (A-Z) of the PROFINET error messages
- 12.2 Possible causes and remedies
- PROFINET: Exist. conn. to 8400 lost [0x01bc3100]
- PROFINET: Memory: No access [0x01bc5531]
- PROFINET: Memory: Read error [0x01bc5532]
- PROFINET: Memory: Write error [0x01bc5533]
- PROFINET: Restart by watchdogreset [0x01bc6010]
- PROFINET: Internal error [0x01bc6011]
- PROFINET: Internal error [0x01bc6100]
- PROFINET: Internal error [0x01bc6101]
- PROFINET: Invalid parameter set [0x01bc641f]
- PROFINET: Error: Lenze setting loaded [0x01bc6420]
- PROFINET: Invalid module configuration [0x01bc6430]
- PROFINET: Record Parameter: Invalid read [0x01bc6501]
- PROFINET: Record Parameter: Invalid write [0x01bc6502]
- PROFINET: Invalid output data [0x01bc6503]
- PROFINET: Data_Exchange status quit [0x01bc6531]
- PROFINET: Station name error [0x01bc6532]
- PROFINET: IP address error [0x01bc6533]
- PROFINET: Stack init error [0x01bc6534]
- PROFINET: Internal error [0x01bc6650]
- 13 Parameter reference
- 13.1 Parameters of the communication module
- C13000 | IP address
- C13001 | Subnetwork mask
- C13002 | Gateway address
- C13003 | Physical address
- C13010 | Active IP address
- C13011 | Active subnetwork mask
- C13012 | Active gateway address
- C13850 | All words to master
- C13851 | All words from master
- C13852 | All words to standard device
- C13853 | All words from standard device
- C13860 | Settings
- C13861 | Bus status
- C13862 | Bus counter
- C13864 | Active station name
- C13867 | Display: Most recent diagnostic data
- C13877 | Bus error(1)
- C13878 | Bus error(2)
- C13880 | Reaction on communication failure
- C13881 | Reaction time delay
- C13885 | Clear process data
- C13887 | Suppress signalling diag. mess. upon
- C13899 | Station name
- C13900 | Firmware product type
- C13901 | Firmware compilation date
- C13902 | Firmware version
- C13910 | I&M1 System designation
- C13911 | I&M1 Installation site
- C13912 | I&M2 Installation date
- C13913 | I&M3 additional information
- C13914 | I&M4 signature code
- 13.2 Table of attributes
- 13.1 Parameters of the communication module
- 14 Index
- Contents