Lenze E94AYCPM User Manual
Profibus, Ä.k6ôä
Table of contents
Document Outline
- E94AYCPM communication module (PROFIBUS®)
- Contents
- 1 About this documentation
- 2 Safety instructions
- 3 Product description
- 4 Technical data
- 5 Installation
- 6 Commissioning
- 7 Data transfer
- 8 Process data transfer
- 9 Parameter data transfer
- 9.1 Addressing of the parameter data
- 9.2 DRIVECOM parameter data channel (DP-V0)
- 9.3 PROFIdrive parameter data channel (DP-V1)
- 9.4 Consistent parameter data
- 10 PROFIsafe
- 11 Monitoring
- 12 Diagnostics
- 13 Error messages
- 13.1 Short overview of the PROFIBUS error messages
- 13.2 Possible causes and remedies
- Profibus: Lost connection to 9400 standard device [0x00c83100]
- Profibus: No memory access [0x00c85531]
- Profibus: Read memory error [0x00c85532]
- Profibus: Write memory error [0x00c85533]
- Profibus: Restart after watchdog reset [0x00c86010]
- Profibus: Internal error [0x00c86011]
- Profibus: Internal error [0x00c86100]
- Profibus: Internal error [0x00c86101]
- Profibus: Internal mapping error [0x00c86110]
- Profibus: Invalid parameter set [0x00c8641f]
- Profibus: Error: Lenze setting loaded [0x00c86420]
- Profibus watchdog: Monitoring time elapsed [0x00c88130]
- Profibus: Data_Exchange state exited [0x00c88131]
- Profibus watchdog: DP-V1 MSAC2 elapsed [0x00c88132]
- 14 Parameter reference
- 14.1 Communication-relevant parameters of the standard device
- 14.2 Parameters of the communication module for slot MXI1
- C13231 | Service code
- C13489 | Service code
- C13531 | Service code
- C13789 | Service code
- C13850 | All words to master
- C13851 | All words from master
- C13852 | All words to standard device
- C13853 | All words from standard device
- C13854 | COM word to standard device
- C13855 | COM word from standard device
- C13860 | Settings
- C13861 | Bus status
- C13862 | Bus counter
- C13863 | Baud rate
- C13864 | Active station address
- C13865 | Display: Most recent PRM data
- C13866 | Display: Most recent CFG data
- C13867 | Display: Most recent diagnostic data
- C13868 | Display: DP state
- C13880 | Reaction on communication fault
- C13881 | Monitoring time: Data exchange
- C13882 | Monitoring time: Watchdog
- C13885 | Clear process data
- C13886 | Set ext. diagnostic bit upon
- C13887 | Suppress signalling diag. mess. upon
- C13897 | PROFIsafe: Target address
- C13899 | Station address
- C13900 | Firmware product type
- C13901 | Firmware compilation date
- C13902 | Firmware version
- C13920 | Display: DIP switch setting
- C13990 | ICM statistic counter
- 14.3 Parameters of the communication module for slot MXI2
- C14231 | Service code
- C14489 | Service code
- C14531 | Service code
- C14789 | Service code
- C14850 | All words to master
- C14851 | All words from master
- C14852 | All words to standard device
- C14853 | All words from standard device
- C14854 | COM word to standard device
- C14855 | COM word from standard device
- C14860 | Settings
- C14861 | Bus status
- C14862 | Bus counter
- C14863 | Baud rate
- C14864 | Active station address
- C14865 | Display: Most recent PRM data
- C14866 | Display: Most recent CFG data
- C14867 | Display: Most recent diagnostic data
- C14868 | Display: DP state
- C14880 | Reaction on communication fault
- C14881 | Monitoring time: Data exchange
- C14882 | Monitoring time: Watchdog
- C14885 | Clear process data
- C14886 | Set ext. diagnostic bit upon
- C14887 | Suppress signalling diag. mess. upon
- C14897 | PROFIsafe: Target address
- C14899 | Station address
- C14900 | Firmware product type
- C14901 | Firmware compilation date
- C14902 | Firmware version
- C14920 | Display: DIP switch setting
- C14990 | ICM statistic counter
- 14.4 Table of attributes
- 14.5 Implemented PROFIdrive objects (DP-V1)
- 15 DIP switch positions for setting the station address
- Index
- Your opinion is important to us
- Contents