5function blocks – Lenze E94A User Manual
Page 441

Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05
441
5
Function blocks
5.114
L_PosSequencer - sequence control
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Parameter
The available actions 1 ... 50 are indicated via the subcodes 1 ... 50.
Parameter
Possible settings
Information
C04510/1...50
Text
Comment on positioning step
• Option for description of the func-
tion for keypad/HMI.
C04511/1...50
Input for waiting function
• With the default setting "0" the
waiting function is skipped and
the profile execution is started
immediately.
0 Waiting function is deactivated.
1 Sequencer input 1
(Bit 0 of dwDigitalInputs)
2 Sequencer input 2
(Bit 1 of dwDigitalInputs)
... ...
32 Sequencer input 32
(Bit 31 of dwDigitalInputs)
C04512/1...50
Signal state for waiting function
• Only when the input for the wai-
ting function has adopted this
state, the profile is executed.
0 Profile start when bit state is "0"
1 Profile start when bit state is "1"
C04513/1...50
Profile number
• A sequence profile can be set in
the corresponding profile para-
meter.
0 No profile execution.
1...100 Execute profile no. 1 ... 100.
C04514/1...50
Sequence step
• Step inside the sequence table
which will be processed after the
profile has been executed.
0 Sequence step
1...100 Step 1 ... 100
C04515/1...50
Watchdog time
• Monitoring time within which po-
sitioning must be completed.
Otherwise, there will be a branch
to the next watchdog step defi-
ned under C04516.
0 Monitoring function is deactivated.
> 0 Monitoring time in [s]
C04516/1...50
Watchdog sequence step
• Executed when the watchdog
time is exceeded.
0 Sequence step
1...100 Step 1 ... 100