5function blocks – Lenze E94A User Manual
Page 256

5
Function blocks
5.66
L_DevBrakeStateDecoder - status signals of the basic function "Brake control"
256
Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Outputs
The boolean outputs have the following meaning when the value is TRUE:
Bit*
Identifier
Meaning in case of TRUE
1 bActive
Brake control is active.
4 bModulUsed
Brake module is used.
8 bBrakeReleased
Brake status (internal status signal).
15 bErrorActive
Brake error is active (collective message).
16 bGrindIn
Status "Brake grinding-in".
17 bTorqueTest
Status "Brake test".
18 bDirectMode
Status "Direct control".
19 bAutoMode
Status "Automatic control".
20 bErrExtFeedback
Error: External feedback.
21 bErrPosDrift
Error: Position drift when brake is applied/during brake test.
22 bErrModul
Error: Brake module monitoring.
23 bTimeActivate
Information: Brake activation via waiting time.
24 bGrindInDone
Information: Brake grinding-in is completed.
25 bTorqueTestDone
Information: Brake test is completed.
26 bErrorTorqueCtrl
Error: feedforward control torque could not be established within one second.
27 bSpeedBelowMin-
Speed
Information: Current speed has fallen below the threshold for the brake activation
set in C02581.
* Relating to the input signal dnState.