L_DevReadParDInt - reading parameters of the DINT type
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.74
L_DevReadParDInt - reading parameters of the DINT type
This FB reads parameters of data type "DINT" and outputs the read value via the output dnData for
the application.
• Only internal parameters (codes) of the controller can be read.
• In contrast to the
FB, the parameter of this FB to be read is addressed via pa-
rameters and not via FB inputs.
• The FB supports both one-time and cyclic reading in a parameterisable time interval.
• To read a parameter with another data type than "DINT", use the FB
Inputs
Function library:
LenzeDevice9400
FB is available from library V02.00.xx.xx onwards!
FB may only be used for firmware from V1.50 onwards!
Runtime software licence:
Motion Control HighLevel
Motion Control TopLevel
Note!
The following applies to the 9400 ServoPLC: The FB may not be called with the same in-
stance in several tasks.
Identifier/data type
Information/possible settings
bExecute
BOOL
Activate a read request.
FALSETRUE If cycle time (C05915) = "0 s":
Read parameter value once which has been addressed via
C05910 ...C05913.
If cycle time (C05915) > "0 s":
Read parameter value cyclically which has been addressed via
C05910 ...C05913.
TRUEFALSE Deactivate cyclic reading again.