Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05

527

5

Function blocks

5.140

L_SdSpeedSet - setpoint ramp generator

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C04228

-214000.0000

Unit/t

214000.0000 Setpoint speed

• Read only

C04229

String from AxisData

Speed unit

• Read only

C04237

-200.00

%

200.00 External setpoint

• Display of the

dnExtSpeedSetpoint_n input sig-

nal.

C04238

-200.00

%

200.00 Current motor speed

• Display of the

dnActualMotorSpeed_n input sig-

nal.

C04239/1

Reverse setpoint

• Display of the bInvertSetpoint in-

put signal.

0 Setpoint not inverted
1 Setpoint inverted

C04239/2

Hold setpoint output

• Display of the bHoldOutput input

signal.

0 Setpoint output enabled
1 Hold setpoint output

C04239/3

Stop

• Display of the bStop input signal.

0 Stop not active
1 Stop requested

C04239/4...7

Jog input 1 ... 8

• Display of the bJog1 ... bJog8 input

signals.

0 Jog input not active
1 Jog input active

C04239/8...11

Ti input 1 ... 8

• Display of the bTi1 ... bTi8 input si-

gnals.

0 Ti input not active
1 Ti input active

C04239/12

Load external setpoint

• Display of the

bLoadExtSpeedSetpoint input sig-

nal.

0 Loading not active
1 Load external setpoint

C04239/13

Load motor speed

• Display of the

bLoadActualMotorSpeed input si-

gnal.

0 Loading not active
1 Load motor speed

Parameter

Possible settings

Information