5function blocks – Lenze E94A User Manual
Page 527

Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05
527
5
Function blocks
5.140
L_SdSpeedSet - setpoint ramp generator
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C04228
-214000.0000
Unit/t
214000.0000 Setpoint speed
• Read only
C04229
String from AxisData
Speed unit
• Read only
C04237
-200.00
%
200.00 External setpoint
• Display of the
dnExtSpeedSetpoint_n input sig-
nal.
C04238
-200.00
%
200.00 Current motor speed
• Display of the
dnActualMotorSpeed_n input sig-
nal.
C04239/1
Reverse setpoint
• Display of the bInvertSetpoint in-
put signal.
0 Setpoint not inverted
1 Setpoint inverted
C04239/2
Hold setpoint output
• Display of the bHoldOutput input
signal.
0 Setpoint output enabled
1 Hold setpoint output
C04239/3
Stop
• Display of the bStop input signal.
0 Stop not active
1 Stop requested
C04239/4...7
Jog input 1 ... 8
• Display of the bJog1 ... bJog8 input
signals.
0 Jog input not active
1 Jog input active
C04239/8...11
Ti input 1 ... 8
• Display of the bTi1 ... bTi8 input si-
gnals.
0 Ti input not active
1 Ti input active
C04239/12
Load external setpoint
• Display of the
bLoadExtSpeedSetpoint input sig-
nal.
0 Loading not active
1 Load external setpoint
C04239/13
Load motor speed
• Display of the
bLoadActualMotorSpeed input si-
gnal.
0 Loading not active
1 Load motor speed
Parameter
Possible settings
Information