5
Function blocks
5.71
L_DevParReadFix - read parameter
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Step 1: Activate SDO server channel 2
To gain read access via the L_DevParReadFix FB, the remote node ("9400 server") must have a para-
meterised SDO server channel suitable for this purpose. SDO server channels 2 ... 10 can be set via
codes C00372 and C00373 at the 9400 server.
• Subcodes 2 ... 10 stand for SDO server channels 2 ... 10.
• To activate SDO server channel 2, a receive identifier (RX identifier) must be entered in C00372/
2 and a transmit identifier (TX identifier) must be entered in C00373/2 at the 9400 server:
[5-35] Activation of parameter data channel 2 at the 9400 server
Now SDO server channel 2 which has been activated at the 9400 server can be used for communi-
cation via a client.