4 deactivation function, 5function blocks – Lenze E94A User Manual
Page 492

5
Function blocks
5.130
L_SdMotorPot - motor potentiometer
492
Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.130.4
Deactivation function
If the control input bDisable is set to TRUE, the control inputs bUp and bDown are deactivated and
the output value dnOut_n is changed according to the deactivation function set in C04362:
C04362
Deactivation function
0
dnOut_n maintains its last value.
1
dnOut_nis increased to 0 % with the deceleration time or increased with the acceleration ti-
me.
2
dnOut_n is decreased to the lower limit value (C04360/2) with the deceleration time
(C04361/2).
3
dnOut_n is increased to the upper limit value (C04360/1) with the acceleration time
(C04361/1).
11
dnOut_n is set to 0 % immediately.
12
dnOut_n is set to the lower limit value (C04360/2) immediately.
13
dnOut_n is set to the upper limit value (C04360/1) immediately.
Note!
If the motor potentiometer function is reactivated and dnOut_n is beyond the limit va-
lues parameterised, dnOut_n is lead to the nearest limit value under consideration of the
acceleration/deceleration time.
This process is independent of the control signals bUp and bDown.