5function blocks – Lenze E94A User Manual
Page 260

5
Function blocks
5.68
L_DevHomingStateDecoder - status signals of the basic function "Homing"
260
Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Outputs
The boolean outputs have the following meaning when the value is TRUE:
Bit*
Identifier
Meaning in case of TRUE
1 bActive
Homing is active.
2 bDone
Homing is completed.
3 bAccDec
Acceleration/deceleration phase is active.
5 bCcw
Counter-clockwise rotation is active.
7 bHomePosOK
Home position is known.
15 bErrorActive
Error is active.
16 bRefMarkDetect
Pre-stop (home switch) has been detected.
17 bTPDetect
Touch probe/zero pulse has been detected.
19 bMinOverride
**
Override ≤ 1 %
21 bLimProfile
Profile data is limited by the basic function "Limiter" (SB LS_Limiter).
22 bLimDir
Direction is inhibited by the basic function "Limiter" (SB LS_Limiter).
23 bLimAbort
Abort by basic function "Limiter" (SB LS_Limiter).
25 bStoppingActive
Stopping (standard stop) is active.
30 bErrPG
Error during profile generation.
* With regard to the dnState input signal.
** As of library V02.04.xx.xx