5

Function blocks

5.142

L_SdSwitchPoint - position switch points

534

Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.142.1

Monitoring for counter overflow

This function extension will be available from library V2.02!

If the machine parameters transferred to the FB via the AxisData input are changed afterwards (e.g.

the gearbox factors), this may cause a counter overflow when the position values defined via

C04397/1...8 and C04398/1...8 converted from the real unit to the internal unit.
The FB causes a corresponding error message in case of an internal counter overflow due to a chan-

ged measuring system:

Error number

Error message in the logbook

Response

61603846

0x3AC0006

L_SdSwitchPoint:int.pos. overflow (LS_DriveInterface)

Error

61603974

0x3AC0086

L_SdSwitchPoint:int.pos. overflow (L_SdSetAxisData)

Error