Page 279

Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05
279
5
Function blocks
5.74
L_DevReadParDInt - reading parameters of the DINT type
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C05914
0.000
s
10.000 Time-out time
• Time in which the read request
must have been processed.
• Initialisation: 0.000 s
C05915
0.000
s
100.000 Cycle time
• Interval for the cyclic reading of a
parameter.
• Initialisation: 0.000 s
(cyclic reading is deactivated)
Note!
The cycle time set in C05915 applies only to the use of the FB in a 1-ms task! For a longer
task cycle the cycle time is prolonged accordingly:
If the FB is used in the unsolicited task, the cycle time set is not effective. In this case use
an upstream FB
instead, in order to cyclically trigger the read request:
• Connect the output bOut of FB
with the input bExecute.
• Set the desired cycle time via the parameters of the FB
.
Parameter
Possible settings
Info
Cycle time
C5915 [s] Task cycle [ms]
⋅
1 [ms]
-------------------------------------------------------------------
=