5function blocks – Lenze E94A User Manual
Page 159

Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05
159
5
Function blocks
5.5
L_CamPosMarker - reading out position marks from cam data
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Parameter
dnXPosMarker2_p
DINT
Position marker 2: x position in [increments]
• C05536/3 indicates the position in the real unit of the machine.
dnYPosMarker2_p
DINT
Position marker 2: y position in [increments]
• C05537/3 indicates the position in the real unit of the machine.
dnXPosMarker3_p
DINT
Position marker 3: x position in [increments]
• C05536/4 indicates the position in the real unit of the machine.
dnYPosMarker3_p
DINT
Position marker 3: y position in [increments]
• C05537/4 indicates the position in the real unit of the machine.
dnXPosMarker4_p
DINT
From library V01.02.xx.xx
Position marker 4: x position in [increments]
• C05536/5 indicates the position in the real unit of the machine.
dnYPosMarker4_p
DINT
From library V01.02.xx.xx
Position marker 4: y position in [increments]
• C05537/5 indicates the position in the real unit of the machine.
dnXPosMarker5_p
DINT
From library V01.02.xx.xx
Position marker 5: x position in [increments]
• C05536/6 indicates the position in the real unit of the machine.
dnYPosMarker5_p
DINT
From library V01.02.xx.xx
Position marker 5: y position in [increments]
• C05537/6 indicates the position in the real unit of the machine.
dnXPosMarker6_p
DINT
From library V01.02.xx.xx
Position marker 6: x position in [increments]
• C05536/7 indicates the position in the real unit of the machine.
dnYPosMarker6_p
DINT
From library V01.02.xx.xx
Position marker 6: y position in [increments]
• C05537/7 indicates the position in the real unit of the machine.
dnXPosMarker7_p
DINT
From library V01.02.xx.xx
Position marker 7: x position in [increments]
• C05536/8 indicates the position in the real unit of the machine.
dnYPosMarker7_p
DINT
From library V01.02.xx.xx
Position marker 7: y position in [increments]
• C05537/8 indicates the position in the real unit of the machine.
XAxisData
Machine parameters of the x axis
• Via this output the machine parameters used by the FB can be easily transferred
to subsequent FBs.
YAxisData
Machine parameters of the y axis
• Via this output the machine parameters used by the FB can be easily transferred
to subsequent FBs.
bError
BOOL
"Error" status
TRUE An error has occurred (group signal).
• For details see display parameter C05539.
Parameter
Possible settings
Information
C05530/1
String of digits
Position unit of x axis
• Read only
C05530/2
String of digits
Designation of the x axis
• Read only
C05530/3
String of digits
Position unit of y axis
• Read only
C05530/4
String of digits
Designation of the y axis
• Read only
Identifier/data type
Value/meaning