Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05

171

5

Function blocks

5.7

L_CamSetContDataPDO - contactor data selection via inputs/PDOs

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.7.1

Exception handling

The following table contains the behaviour of the FB in various special cases:

5.7.2

Interconnection example

[5-15] Interconnection example: Selection of the cam data via PDOs

Special case

Behaviour

Invalid axis data

The bError output is set to TRUE.

Wrong parameterisation of the contactor data

A cam track is output without the wrong cams.

Selection of an invalid cam number

The number of cams is limited to 8, i.e. a cam track with

max. 8 cams is output.

In this case, the bError output is not set to TRUE.

Selection of an invalid cam type

No cam track is output.

The bError output is set to TRUE.