5.138

L_SdSetSpeed - speed conversion

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.138.1

Monitoring for counter overflow

This function extension will be available from library V2.02!

If the machine parameters transferred to the FB via the AxisData input are changed afterwards (e.g.

the gearbox factors), this may cause a counter overflow when the speed value defined via C04286

is converted from the real unit to the internal unit.
The FB reports an internal counter overflow due to a changed measuring system by the value "-12"

at the dnState status output and activates a corresponding error message:

Error number

Error message in the logbook

Response

61603845

0x3AC0005

L_SdSetSpeed:int.speed overflow (LS_DriveInterface)

Error

61603973

0x3AC0085

L_SdSetSpeed:int.speed overflow (L_SdSetAxisData)

Error