Working with the FB editor

3.4

Creating/reconfiguring the interconnection

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Insert a variable into the interconnection
A variable contained in the list field can be inserted exactly once with an input (for value assign-

ment) into the interconnection and as often as required with an output (for read access).

How to insert a variable into the interconnection:

1. Go to the Insert variables dialog box and select the variable to be inserted in the list field.
2. Press the Insert (with output) or Insert (with input) button to insert a variable with input or

output into the interconnection.

Related topics:

Deleting objects that are no longer required

( 70)

Deleting variables and user codes from the application

( 71)

Arranging objects in the drawing area

( 73)

Creating/deleting connections

( 74)

Note!

Variables are only assigned at the end of the task cycle! Thus, the variable value will only

be effective in the next task cycle!