Function blocks

5.114

L_PosSequencer - sequence control

440

Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.114.3.2 Action type "Positioning"

To execute a profile, 50 actions of "Positioning" type are available.

Action call (entry in the sequence table)

with action number xxx = 001 ... 050

Waiting function
The execution of the set profile with activated waiting function is only started if the bit 1 ... 32 of the

input signal dwDigitalInputs selected for the waiting function adopts the selected signal state ("0"

or "1").

"Watchdog" monitoring function
You can select an individual "watchdog time" for every "positioning" action.

• If positioning takes longer than the selected watchdog time, there will be a branch to the next

watchdog step.

• If the watchdog time is set to 0 s, the monitoring function is deactivated (Lenze setting).