5function blocks – Lenze E94A User Manual
Page 182

5
Function blocks
5.10
L_CamStretchFeed - stretching/compressing the position (relative)
182
Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Parameter
Parameter
Possible settings
Information
C05440/1
String of digits
Position unit
• Read only
C05440/2
String of digits
Speed unit
• Read only
C05447
-214748.3647
Unit
214748.3647 Input position
• Display of the dnPosIn_p input si-
gnal in the real unit of the machi-
ne.
C05448
-214748.3647
Unit/t
2
214748.3647 Input acceleration feedforward cont-
rol
• Display of the dnAccIn_x input si-
gnal in the real unit of the machi-
ne.
C05449
-214748.3647
Unit
214748.3647 Feed length
• Display of the dnFeedLength_p in-
put signal in the real unit of the
machine.
C05450
-214748.3647
214748.3647 Effective stretch factor
C05451
-214748.3647
Unit
214748.3647 Starting position
• Display of the dnStartPos_p input
signal in the real unit of the ma-
chine.
C05455
-214748.3647
Unit
214748.3647 Output position
• Display of the dnPosOut_p output
signal in the real unit of the ma-
chine.
C05456
-214748.3647
Unit/t
214748.3647 Output speed
• Display of the dnSpeedOut_s out-
put signal in the real unit of the
machine.
C05457
-214748.3647
Unit/t
2
214748.3647 Output acceleration feedforward
control
• Display of the dnAccOut_x output
signal in the real unit of the ma-
chine.
C05458/1
-214748.3647
Unit
214748.3647 Stretched position
• Display of the dnStretchPos_p out-
put signal in the real unit of the
machine.
C05458/2
-214748.3647
Unit
214748.3647 Stretched feed length
• Read only
C05459
Status messages:
Status (bit coded)
• Bits that are not itemised are re-
served for future extensions.
• The bError error output will only
be set to TRUE if an error message
(bit 16 ... 31) is issued.
• Bit 31 is the default setting if one
or more other error bits (bit 16 ...
30) are set.
bit 10 Zero crossing active
Error messages:
bit 16 dnStartPos_p is beyond the cycle
bit 17 Initial speed too high
bit 23 Invalid axis data structure
bit 24 Stretched position too great
bit 31 General error