93 l_ldmpot - master value adjustment, L_ldmpot, 5function blocks – Lenze E94A User Manual
Page 337

Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05
337
5
Function blocks
5.93
L_LdMPot - master value adjustment
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.93
L_LdMPot - master value adjustment
This FB serves to execute a master value adjustment.
Inputs
Function library:
LenzeLineDrive
Runtime software licence:
Motion Control HighLevel
Motion Control TopLevel
Identifier/data type
Information/possible settings
bEnable
BOOL
Activate master value adjustment
FALSE Master value adjustment is/will be deactivated.
• Output dnSpeedOut_s is braked to standstill via the disable ramp,
if required.
TRUE Master value adjustment is activated.
bJogPositive
BOOL
Adjustment in positive traversing direction
FALSE Output dnSpeedOut_s is braked to standstill via the deceleration
ramp.
TRUE Output dnSpeedOut_s is led to positive speed (C05122) via the start-
up ramp.
bJogNegative
BOOL
Adjustment in negative traversing direction
FALSE Output dnSpeedOut_s is braked to standstill via the deceleration
ramp.
TRUE Output dnSpeedOut_s is led to negative speed (C05123) via the start-
up ramp.
AxisData
Machine parameters
• For accepting the machine parameters of the drive/motor, connect this input
with the output DI_AxisData of the SB LS_DriveInterface.
• The machine parameters of a master drive can be displayed with the
FB
. In this case, the FB output AxisData must be connected to
this input.