Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05

519

5

Function blocks

5.137

L_SdSetPosition - position conversion

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.137.1

Monitoring for counter overflow

This function extension will be available from library V2.02!

If the machine parameters transferred to the FB via the AxisData input are changed afterwards (e.g.

the gearbox factors), this may cause a counter overflow when the position value defined via C04276

is converted from the real unit to the internal unit.
The FB reports an internal counter overflow due to a changed measuring system by the value "-12"

at the dnState status output and activates a corresponding error message:

Error number

Error message in the logbook

Response

61603844

0x3AC0004

L_SdSetPosition:int.pos. overflow (LS_DriveInterface)

Error

61737217

0x3AE0901

L_SdSetPosition:int.pos. overflow (L_SdSetAxisData)

Error