L_tbdifferentiate, 5function blocks – Lenze E94A User Manual
Page 582

5
Function blocks
5.168
L_TbDifferentiate - differentiator with low-pass filter
582
Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.168
L_TbDifferentiate - differentiator with low-pass filter
This FB represents a differentiator with low pass.
• The input signal is differentiated and filtered with the filter time constant set via the parameter
C04050.
• The dnOut output signal has the unit [1/s] as time reference.
• The dnOut output signal is internally limited to ±2
31
-1.
• The bLimitActive output displays if a limitation is active.
Inputs
Outputs
Parameter
Function library:
LenzeToolbox
Runtime software licence:
Motion Control HighLevel
Motion Control TopLevel
Identifier/data type
Information/possible settings
dnIn
DINT
Input signal
Identifier/data type
Value/meaning
dnOut
DINT
Output signal
• Internally limited to ±2
31
-1
bLimitActive
BOOL
Status signal "Limitation active"
TRUE The output signal is limited.
Parameter
Possible settings
Information
C04050
0.001
s
60.000 Filter time constant T
Filter
• Initialisation: 0.001 s
GQ2XW
E/LPLW$FWLYH
GQ,Q
/B7E'LIIHUHQWLDWH
&
)LOWHUWLPHFRQVWDQW