9 define currents and speed limits, Define currents and speed limits, C 78) – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual
Page 78: 9400 highline | parameter setting & configuration
9400 HighLine | Parameter setting & configuration
Motor interface
Initial commissioning | Define currents and speed limits
78
Firmware 1.37 - 09/2006
L
5.1.9
Define currents and speed limits
Maximum current
In
the required maximum current must be set.
r
In order that the motor does not start unintentionally without adjusting the route data,
the maximum current in the Lenze setting is set to "0 A" in
.
Moreover the motor limit current set in
must be checked and the error response
required for the motor protection must be selected in
Motor reference speed
In
the reference speed of the motor must be set.
Maximum system speed
Adapt the maximum system speed in
and select the error response required when
this speed limit has been reached in
.
Note!
When MCS motors are used check if the motor used exceeds the voltage limit in
the required operating range up to maximum current/reference speed.
• If so, the reference speed must be reduced to a permissible value.
• Presently the controller does not support a field weakening control for
synchronous motors so that an operation at the voltage limit causes an
undefined behaviour.
On the part of the application it must be ensured that maximally 100 % of the
reference speed set in