4.6.5
Save parameter set
Controller parameter changes made via the »Engineer« or keypad will get lost after mains
switching of the controller or loading of another application unless the settings have been
explicitly saved with the corresponding controller command in the memory module of the
controller.
M
How to save the starting parameters safe against mains failure in the memory
module:
Execute the controller command "Save starting parameter" with
= "11".
4.6.6
Load parameter set
Activation of this controller command reloads the parameter set of the active application
from the memory module into the controller. All parameter changes made since the
parameter set has been saved last will get lost.
r
Only possible when the application program has stopped and the controller is
inhibited.
M
How to reload the starting parameters from the memory module:
1. Click the icon to stop the current controller program.
2. Click the icon to set the controller inhibit.
3. Execute the controller command "Load starting parameter" with