Diagnostics & error analysis
Error messages of the operating system
Logbook: overflow [0x00650000]
Logbook: reset (read error) [0x00650001]
Logbook: reset (version error) [0x00650002]
Memory module missing [0x00650003]
Control card is defective [0x00680000]
Power section is defective [0x00680001]
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning : Information
Cause
Remedy
Too many events/errors have occurred in a very short
time. It was therefore not possible to list all of them in
the logbook.
Check if application generates too many error messages.
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning : Information
Cause
Remedy
The logbook has been reset due to a read error..
- (is irreversible)
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning : Information
Cause
Remedy
The logbook has been reset due to a version conflict.
- (is irreversible)
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning : Information
Cause
Remedy
Memory module is defective or not available.
Use a different memory module.
Response (Lenze setting printed in bold)
None : System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Operating system could not identify the control card.
Mains switching
• Please contact Lenze, if the error occurs again.
Response (Lenze setting printed in bold)
None : System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Operating system could not identify the power stage.
Mains switching