Negative limit switch has tripped [0x00b80002]
Motor brake: Angular drift with closed brake is too large [0x00b80003]
Motor brake: Automatically activated when the waiting time has elapsed [0x00b80004]
Motor brake: Status monitoring error [0x00b80005]
Response (Lenze setting printed in bold)
None System fault : Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
in negative traversing
direction has tripped.
Reset error message and
.
Response (Lenze setting printed in bold)
None System fault : Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Despite the applied brake, the stop position of the motor
axis has changed by more than the permissible angle of
rotation set in
.
• Deactivate standstill monitoring (
= 0).
• Increase waiting time for status monitoring (
).
The standstill monitoring only starts after this
waiting time has elapsed.
• Increase brake closing time (
) since during the
brake closing time the standstill monitoring is not
active.
• Reduce threshold for brake activation (
).
Response (Lenze setting printed in bold)
None System fault : Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
This time monitoring will only be active if the speed
setpoint has reached the threshold for brake activation
(
).
If the actual speed value does not reach/fall below the
threshold set in
within the parameterised
waiting time for brake activation (
), the brake will
be closed due to time-out.
• Increase waiting time for brake activation (
).
• Reduce threshold for brake activation (
).
Response (Lenze setting printed in bold)
None System fault : Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Faulty external feedback of the brake status to the brake
control.
• Check brake configuration with regard to the control
selection in
.
• Check setting for status input monitoring in
When monitoring is active, the bBrakeApplied input
must be triggered correctly (bBrakeApplied =
bBrakeReleased).
• Check voltage supply of the brake module.