11 limiter, 9400 highline | parameter setting & configuration – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual
Page 320
![background image](/manuals/566320/320/background.png)
9400 HighLine | Parameter setting & configuration
TAs for interconnection via electrical shaft
TA "Electronic gearbox" | Limiter
320
Firmware 1.37 - 09/2006
L
12.2.11
Limiter
[12-21] Basic function "Limiter" (schematic diagram)
r
Parameter setting: Tab Application parameter Dialog level Overview Limiter
The basic function "Limiter" monitors the
travel range limits via limit switches and
parameterised software limit positions
and can lead the drive to defined limit
ranges when being asked accordingly by
the safety module.
v
t
t
M
Slave
n
t
LS_Limiter
n
t
LS_Quickstop
STOP
Parameters
Lenze setting
Value Unit
Limit values
Permissible direction of rotation
Positive and negative
Software limit positions are active
Deactivated
Positive software limit position
0.0000 Unit
Negative software limit position
0.0000 Unit
Only for homing, positioning and manual jog
Limitations effective
Deactivated
Max. speed
3600.0000 Unit/s
Max. acceleration
3600.0000 Unit/s
2
Min. S-ramp time
100 ms
Limited speed 1 ... 4 (only for homing, positioning, and manual jog)
Limited speed 1
3600.0000 Unit/s
Delay lim. speed 1
0.0100 Unit/s
2
S-ramp time lim. speed 1
100 ms
Limited speed 2
7200.0000 Unit/s
Delay lim. speed 2
0.0100 Unit/s
2
S-ramp time lim. speed 2
100 ms
Limited speed 3
14400.0000 Unit/s
Delay lim. speed 3
0.0100 Unit/s
2
S-ramp time lim. speed 3
100 ms
Limited speed 4
28800.0000 Unit/s
Delay lim. speed 4
0.0100 Unit/s
2
S-ramp time lim. speed 4
100 ms
For manual jog only
Max. path - manual jog
360.0000 Unit