C02716, C02717, C02718 – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual
Page 642: C02719, C02716/1, C02716/2, C02716/3, Parameterised in, Takes place, The response parameterised in
9400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C02716
642
Firmware 1.37 - 09/2006
L
C02716
C02717
C02718
C02719
Parameter | Name:
C02716 | Resp. to limitation
Data type: UNSIGNED_32
Index: 21859
d
= 5563
h
Basic function "
Selection list
0 No response
1 Error
2 Trouble
3 Quick stop by trouble
4 Warning locked
5 Warning
6 Information
Subcodes
Lenze setting
Information
C02716/1
0: No response
Resp. to rotation limitation
C02716/2
3: Quick stop by trouble
Resp. to SW limit pos. excess
C02716/3
0: No response
Resp. to max. value excess
;
Read access ; Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C02717 | LIM_dwControl
Data type: UNSIGNED_32
Index: 21858
d
= 5562
h
Control word of the basic function "
" (LS_Limiter).
Display range
(min. value | unit | max. value)
0
4294967295
;
Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C02718 | LIM_dnState
Data type: INTEGER_32
Index: 21857
d
= 5561
h
Status of the basic function "
Display range
(min. value | unit | max. value)
0
1
;
Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C02719 | Limiter: Dig. signals
Data type: UNSIGNED_32
Index: 21856
d
= 5560
h
Display of the boolean input signals of the basic function "
" (LS_Limiter).
Selection list
0 FALSE
1 TRUE
Subcodes
Information
C02719/1
LIM_bLimitSwitchPositive
C02719/2
LIM_bLimitSwitchNegative
C02719/3
LIM_bActivateLimitedSpeed1
;
Read access Write access CINH PLC STOP No transfer COM MOT