Parameter set saved [0x00900002, Parameter set loaded [0x00900003, Loading of lenze setting failed [0x00900004 – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual
Page 496: Parameter set restored [0x00900005, Saving of parameters failed [0x00900006, Parameter set: version conflict [0x00900007, 9400 highline | parameter setting & configuration
![background image](/manuals/566320/496/background.png)
9400 HighLine | Parameter setting & configuration
Diagnostics & error analysis
Error messages of the operating system
496
Firmware 1.37 - 09/2006
L
Parameter set saved [0x00900002]
Parameter set loaded [0x00900003]
Loading of Lenze setting failed [0x00900004]
Parameter set restored [0x00900005]
Saving of parameters failed [0x00900006]
Parameter set: Version conflict [0x00900007]
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning : Information
Cause
Remedy
Parameter set has been saved.
- (Information only)
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning : Information
Cause
Remedy
Parameter set has been loaded.
- (Information only)
Response (Lenze setting printed in bold)
None System fault : Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Lenze setting of a parameter is not within the valid
limits.
Remove error in the application and retransmit the
application to the controller.
Response (Lenze setting printed in bold)
None System fault : Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
An error has occurred while loading the selected
parameter set.
Transfer parameter set from Engineer to the controller
and save with
Response (Lenze setting printed in bold)
None System fault : Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
An error has occurred while saving the current
parameter set.
Use a different memory module.
Response (Lenze setting printed in bold)
None System fault : Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
The parameter set version on the memory module is not
compatible with the firmware of the controller.
Transfer parameter set from Engineer to the controller
and save with