11 interrupting/replacing states, 12 priorities, 9400 highline | parameter setting & configuration – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual
Page 145

L
Firmware 1.37 - 09/2006
145
9400 HighLine | Parameter setting & configuration
Basic drive functions
General information | Internal state machine
9.1.2.11
Interrupting/replacing states
An active function state cannot be interrupted or replaced by the activation of another
function state. However, the following exceptions apply:
r
The "Initialisation" state replaces all other states.
r
The "Error" state can replace all other states except "Initialisation".
r
The status "Controller not ready" can replace all other states except "Error" and
"Initialisation".
r
The status "Quick stop active" can replace all other states except "Initialisation", "Error"
and "Controller not ready".
9.1.2.12
Priorities
The function states are assigned to priorities so that, if several basic functions are activated
at the same time, it is always changed to the function state with the highest priority:
Priority
Function state
Executable basic function
1
Initialisation
-
2
Error
-
3
Controller not ready
-
4
Quick stop active
5
Manual jog active
6
Homing active
7
Positioning active
8
Setpoint follower (position) active
9
Setpoint follower (speed) active
10
Setpoint follower (torque) active
10
Brake check
12
Drive is stopped
1 ≡ highest priority; 1 2≡ lowest priority
Note!
The basic state "Drive in standstill" is accepted automatically if no other state is
active.