2 parameter setting, 1 setpoint interpolation, 2 inversion of the direction of rotation – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual
Page 197: Setpoint interpolation, Inversion of the direction of rotation, 9400 highline | parameter setting & configuration
L
Firmware 1.37 - 09/2006
197
9400 HighLine | Parameter setting & configuration
Basic drive functions
Torque follower | Parameter setting
9.9.2
Parameter setting
r
Parameterisation dialog in the »Engineer«: Tab Application parameter dialog level
Overview All basic functions Torque follower
r
Short overview of the parameters for the torque follower:
9.9.2.1
Setpoint interpolation
When the setpoint interpolation is activated, the motor control creates intermediate
values to "smoothly" follow the speed and/or torque setpoints which may be transferred
from a slower task.
r
= "1": The motor control follows the speed setpoint in interpolated steps.
r
= "1": The motor control follows the torque setpoint in interpolated steps.
9.9.2.2
Inversion of the direction of rotation
Depending on the motor mounting position the direction of rotation can be reversed, if
required:
r
= "0": Clockwise motor ≡ positive machine direction.
r
= "1": Counter-clockwise motor ≡ positive machine direction.
Parameters
Information
Speed setpoint 1
Speed setpoint 2
Speed controller gain
Speed controller reset time
Upper speed limit value
Lower speed limit value
Motor mounting direction
Speed setpoint interpolation
Torque setpoint interpolation
Internal torque limit
Highlighted in grey = display parameter