C00185, C00186, C00187 – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual
Page 562: C00188, C00199, C00200, C00201, 9400 highline | parameter setting & configuration

9400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C00185
562
Firmware 1.37 - 09/2006
L
C00185
C00186
C00187
C00188
C00199
C00200
C00201
Parameter | Name:
C00185 | Threshold - mains recov. detect.
Data type: UNSIGNED_32
Index: 24390
d
= 5F46
h
Setting range
(min. value | unit | max. value)
Lenze setting
0
%
100 90 %
;
Read access ; Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00186 | ENP: Identified motor type
Data type: VISIBLE_STRING
Index: 24389
d
= 5F45
h
Motor type read from the electronic nameplate (ENP)
;
Read access Write access CINH PLC STOP No transfer COM ; MOT
Parameter | Name:
C00187 | ENP: Identified serial number
Data type: VISIBLE_STRING
Index: 24388
d
= 5F44
h
Serial number read from the electronic nameplate (ENP)
;
Read access Write access CINH PLC STOP No transfer COM ; MOT
Parameter | Name:
C00188 | ENP: Status
Data type: UNSIGNED_8
Index: 24387
d
= 5F43
h
Selection list
(display only)
0 No ENP found
1 ENP data loaded
2 Known ENP found
;
Read access Write access CINH PLC STOP No transfer COM ; MOT
Parameter | Name:
C00199 | Device name
Data type: VISIBLE_STRING
Index: 24376
d
= 5F38
h
Device name to be defined by the user (e.g. "Cross cutter" or "hoist axis 1") with max. 128 characters
;
Read access ; Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00200 | Firmware product type
Data type: VISIBLE_STRING
Index: 24375
d
= 5F37
h
;
Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00201 | Firmware - compile date
Data type: VISIBLE_STRING
Index: 24374
d
= 5F36
h
;
Read access Write access CINH PLC STOP No transfer COM MOT