C00003, C00004, If the device command – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual
Page 546: Mean, E controller command activated under, C00002, 9400 highline | parameter setting & configuration

9400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C00003
546
Firmware 1.37 - 09/2006
L
C00003
C00004
203 Activate parameter set 3
Loads parameter set 3 from the memory module.
• Only possible when the application has stopped and
the controller is inhibited.
204 Activate parameter set 4
Loads parameter set 4 from the memory module.
• Only possible when the application has stopped and
the controller is inhibited.
301 Archive parameter set 1
Stores the current parameter set as parameter set 1 in
the memory module.
302 Archive parameter set 2
Stores the current parameter set as parameter set 2 in
the memory module.
303 Archive parameter set 3
Stores the current parameter set as parameter set 3 in
the memory module.
304 Archive parameter set 4
Stores the current parameter set as parameter set 4 in
the memory module.
401 Internal command 401
For Lenze service only
730 Internal command 730
For Lenze service only
731 Internal command 731
For Lenze service only
732 Internal command 732
For Lenze service only
733 Internal command 733
For Lenze service only
800 Internal command 800
For Lenze service only
1001 Internal command 1001
For Lenze service only
1020 Internal command 1020
For Lenze service only
1021 Export parameters to file
Export current parameter set to file.
1030 Format file system
Format file system of the memory module.
1040 Restore file system
10000 Prepare firmware update
11000 Restart controller
;
Read access ; Write access CINH PLC STOP ; No transfer COM MOT
Parameter | Name:
C00002 | Controller commands
Data type: UNSIGNED_32
Index: 24573
d
= 5FFD
h
Parameter | Name:
C00003 | Controller command status
Data type: UNSIGNED_32
Index: 24572
d
= 5FFC
h
Display of the number/status of the device command last executed (
• The number of the command stands in the upper 16 bits (for the meaning of the number, see code
• The result of the command stands in the lower 16 bits.
Display range
(min. value | unit | max. value)
0
4294967295
;
Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00004 | Service password
Data type: UNSIGNED_32
Index: 24571
d
= 5FFB
h
Service code to unlock protected device commands (
Setting range
(min. value | unit | max. value)
Lenze setting
0
4294967295
;
Read access ; Write access CINH PLC STOP ; No transfer COM MOT