Motor: actual speed value > c00596 [0x007b0020, Brake chopper: overcurrent [0x007b0021, 9400 highline | parameter setting & configuration – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual
Page 473
![background image](/manuals/566320/473/background.png)
L
Firmware 1.37 - 09/2006
473
9400 HighLine | Parameter setting & configuration
Diagnostics & error analysis
Error messages of the operating system
Resolver: Calculated acceleration unrealistic [0x007b001f]
Motor: Actual speed value > C00596 [0x007b0020]
Brake chopper: Overcurrent [0x007b0021]
Position encoder: Module selected under C00490 not available [0x007b0023]
Motor encoder: Module selected under C00495 not available [0x007b0024]
Motor temperature: Module selected under C01193 not available [0x007b0025]
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning : Information
Cause
Remedy
Resolver evaluation faulty (implausible acceleration at
the resolver).
Check set-up.
Response (Lenze setting printed in bold)
Setting:
(; Adjustable response)
;
None System fault : Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning Information
Cause
Remedy
Threshold for speed monitoring set in
has been
exceeded.
Check drive dimensioning.
Response (Lenze setting printed in bold)
Setting:
(; Adjustable response)
:
None System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning Information
Cause
Remedy
Brake chopper short circuit/earth fault detected.
Check brake chopper cable and brake resistor.
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
The position encode selected under
recognised.
• Check position encoder.
• Check parameter setting (
).
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
The motor encoder selected under
recognised.
• Check motor encoder.
• Check parameter setting (
).
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
The module for temperature feedback selected in
has not been recognised.
• Check feedback module.
• Check parameter setting (
).