1 starting positioning, 2 aborting/interrupting positioning, 3 continuing an interrupted positioning process – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual
Page 178: Starting positioning, Aborting/interrupting positioning, Continuing an interrupted positioning process, 9400 highline | parameter setting & configuration

9400 HighLine | Parameter setting & configuration
Basic drive functions
Positioning | Carrying out positioning
178
Firmware 1.37 - 09/2006
L
9.6.2.1
Starting positioning
By setting the control input POS_bStart to TRUE positioning starts.
r
The (travel) profile is executed which has been transferred to the basic function via the
input POS_ProfileData.
9.6.2.2
Aborting/interrupting positioning
By setting the control input POS_bAbort to TRUE, the active positioning can be aborted or
interrupted.
r
The current profile is not completed but braked to standstill with the deceleration
defined in the profile data.
r
When the control input POS_bAbort is remained on TRUE, a restart or the continuation
of an interrupted positioning process is inhibited.
r
After resetting the control input POS_bAbort to FALSE, a restart or the continuation of
an interrupted positioning process is possible again.
9.6.2.3
Continuing an interrupted positioning process
By setting the control input POS_bRestart to TRUE an interrupted positioning process can
be continued if the control input POS_bAbort has been reset again to FALSE.
r
Distance already covered in a relative positioning process will be considered.