8 limiter, Limiter, C 258) – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual
Page 258: 9400 highline | parameter setting & configuration
9400 HighLine | Parameter setting & configuration
Standard TAs
TA "Actuator – speed" | Limiter
258
Firmware 1.37 - 09/2006
L
11.2.8
Limiter
[11-11] Basic function "Limiter" (schematic diagram)
r
Parameter setting: Tab Application parameter Dialog level Overview Limiter
O
Tip!
Detailed information on the limiter function can be found in chapter "Basic drive
functions" subchapter "
".
The basic function "Limiter", where
applicable, by means of limit switches
monitors travel range limits.
In the case of homing, positioning and
manual jog the basic function "Limiter" if
required provides for the compliance with
kinematic limit values.
LS_ManualJog
n
t
и
з
LS_Brake
n
t
LS_Limiter
n
t
LS_Quickstop
STOP
LS_Speed...
M
Speed
setpoint
n
t
LS_Stop
internal
status machine
DI2
DI6
DI7
DI8
DI1
Status
machine
(basic drive
functions)
Basic drive functions
M
v
и
з
Note!
The parameterised limit values are not effective for the basic functions "
For the exceeding of the limit values an error response can be set.
Parameters
Lenze setting
Value Unit
Only for homing, positioning and manual jog
Limitations effective
Deactivated
Max. speed
3600.0000 Unit/s
Max. acceleration
3600.0000 Unit/s
2
Min. S-ramp time
100 ms
Permissible direction of rotation
Positive and negative
Control inputs of the function
Signal configuration
Lenze setting
Control input
(Multiplexer parameters)
FALSE Positive limit switch
C03150/1
FALSE Negative limit switch
C03150/2